ZBA ZB-8210 Bedienungsanleitung

Stöbern Sie online oder laden Sie Bedienungsanleitung nach Barcodeleser ZBA ZB-8210 herunter. ZBA ZB-8210 User`s manual Benutzerhandbuch

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken

Inhaltsverzeichnis

Seite 1 - User’s Manual

ZB-8150/ZB-8110/ZB-8210CCD BARCODE SCANNERUser’s ManualZBA Inc 94 Old Camplain Road Hillsborough NJ 08844Phone: 908-359-2070 Fax: 908-359-1272

Seite 2 - Installation:

Keyboard wedge As a keyboard interface, the scanner supports most of the popular PCs and IBM terminals. The installation of the wedge is a fairly sim

Seite 3 - (8210) -

Keyboard wedge Keyboard Layout: The selecting of keyboard layout supports many country languages other than USA keyboard layout. First you need to co

Seite 4 - Code39,PCS=90%

Keyboard layout USA Belgium Danish France Germany Italian Portuguese Spanish Swedish Switzerland UK Latin American 00* 01 02 03 04 05 06 07 08 09 10 1

Seite 5

Keyboard wedge Caps Lock: By selecting Caps Lock or No Caps Lock, scanner can get Caps Lock status. Power-on simulation: All of the PCs check the k

Seite 6

Program Option Bar Code Option Alphanumeric Entry Caps lock Caps lock”ON” Caps lock”OFF”00 01* Power-on simulationDisable Enable 00* 01 Inter-ch

Seite 7 - 8110/8150/8210

RS-232 CTS: Clear To Send (Hardware Signal) RTS: Request To Send (Hardware Signal) Xon: Transmit On (ASCII Code 1116) Xoff: Transmit Off (ASCII Code

Seite 8 - Program Barcode

Program Option Bar Code Option Alphanumeric Entry Flow control None RTS/CTS Xon/Xoff ACK/NAK 00* 01 02 03 Inter-character delay00-99 (msec) 00-9

Seite 9 - Interface Selection

Program Option Bar Code Option Alphanumeric Entry Baud rate 300 BPS 600 BPS 1200 BPS 2400 BPS 4800 BPS 9600 BPS 19200 BPS 38400 BPS 00 01 02 03

Seite 10 - Keyboard wedge

Wand Emulation Bar/space polarity: High/low- Black will be transmitted as a high voltage level (+5) and space as low level (0V). Low/high- Black

Seite 11

Wand Emulation Output speed: This setting is same as serial transmission baud rate, and it must be approbated your wand decode resolution. The unit o

Seite 12

Installation:Keyboard Wedge 1) Turn off the PC2) Disconnect the keyboard cable from the PC. 3) Connect the Keyboard Cable to the scanner and connec

Seite 13

Reserved 00* Reserved 00* Margin delay 00-99 (10 pixel)00-99 15* Transmit delay 00-99 (10 msec)00-99 30* Exit 20

Seite 14

Scan Scanning mode: Good-read off-The trigger button must be pressed to activate scanning. The light source of scanner stops scanning when there i

Seite 15

Program Option Bar Code Option Alphanumeric Entry Scanning mode Good-read off Momentary Alternate Timeout off Continue 00 01* 02 03 04 Stand-

Seite 16

Scan Multi field scan: The scanner can be read many sets of barcode data on the same scanning line at the same time, even if they are different kinds

Seite 17

Multi field scan Disable Enable 00* 01 Global min. code length00-63 00-63 04* Global max.code length00-63 04-63 63* Inverted image scan Disable

Seite 18

Indication Power on alert: After power-on the scanner it will generate an alert signal to indicate a successful self-test. LED indication: After e

Seite 19 - Wand Emulation

Program Option Bar Code Option Alphanumeric Entry Power on alert Disable Enable 00 01* LED indication Disable Enable 00 01* Buzzer indication

Seite 20

UPCA Read: Format Leading Zero Data Digits(11 Digits)Check Digit Check-sum transmission: By setting Enable, checks sum will be transmitted. Truncate

Seite 21

Check-sum verification Disable Enable 00 01* Check-sum transmissionDisable Enable 00 01* Max.code length 00-64 00-64 64* Min.code length 00-64 00-

Seite 22

UPCA Supplement digits: The Supplement digits barcode is the supplemental 2 or 5 characters for

Seite 23

Default Setting for each barcode shown as below: Read Enable Code Type 8110 8150/8210ChecksumVerification Enable ChecksumTransmissionEnable CodeIDUP

Seite 24

UPCE Read: Format Leading Zero Data Digits (6 Digits) Check Digits Check-sum verification: The checksum of EAN-13 is optional and made as the sum of

Seite 25 - Indication

UPCE Truncate leading/ending: Refer to Truncate leading/ending of UPCA. Code Id setting: Refer to Code ID setting of UPCA. Insertion group selectio

Seite 26

Truncate ending 0-15 00-15 00* Code ID setting 00-ffH ASCII code 00-ffH < E >* Insert group selection 00-44 00-44 00* Supplement digits None

Seite 27

EAN-13 Read: Format Data Digits (12 Digits) Check Digits Check-sum verification: The checksum of EAN-13 is optional and made as the sum of the numeri

Seite 28

Check-sum verification Disable Enable 00 01* Check-sum transmission Disable Enable 00 01* Max.code length 00-64 00-64 64* Min.code length 00-64 00-6

Seite 29 - UCC / EAN 128

EAN-13 Code Id setting: Refer to Code ID setting of UPCA. Insertion group selection: Refer to Insertion group selection of UPCA. Supplement digits

Seite 30

Program Option Bar Code Option Alphanumeric Entry Code ID setting 00-ffH ASCII code 00-ffH < F >* Insert group selection 00-44 00-44 00*

Seite 31 - UCC/EAN 128

EAN-8 Read: Format Data Digits (7 Digits) Check Digits Check-sum verification: The checksum of EAN-8 is optional and made as the sum of the numerical

Seite 32

Check-sum transmission Disable Enable 00 01* Max.code length 00-64 00-64 64* Min.code length 00-64 00-64 01* Truncate leading 0-15 00-15 00* Trunca

Seite 33

EAN-8 Supplement digits: Format Data Digits(7 Digits)Check Digits Supplement Digits2 or 5 or UCC/EAN 128 Truncate Leading zero: Refer to Truncate Lea

Seite 34

ZBA ZB- 8110 / 8150 - 1D Barcode scannerSpecification Model 8110 Model 8150 Operational Light Source 660 nm Visible Red LED Optical System 2048 pi

Seite 35

Code 39 Read: Format Start“★” Data Digits( Variable)Checksum(Optional)End“★”Check-sum verification: The checksum of Code-39 is optional and made as

Seite 36

Code 39 Max./Min. code length: Each symbology has own Max./Min. Code Length. They can be set to qualify data entry. If their Max./Min. Code Length is

Seite 37

Max. code length 00-64 00-64 00* Min. code length 00-64 00-64 00* Truncate leading 0-15 00-15 00* Truncate ending 0-15 00-15 00* Code ID setting

Seite 38

Code 39 Append: This function allows several symbols to be concatenates and be treat as one single data entry. The scanner will not transmit the embe

Seite 39

Interleaved 2 of 5 Read: Format Data Digits (Variable) Checksum (Optional) Check-sum verification: The checksum is made as the sum module 10 of the

Seite 40 - Code 39

Interleaved 2 of 5 Max./Min. code length: Refer to Max./Min. code length of Code-39. Truncate leading/ending: Refer to Truncate leading/ending of UP

Seite 41

Code ID setting 00-ffH ASCII code 00-ffH < i >* Insert group selection 00-44 00-44 00* Exit 46

Seite 42

Industrial 2 of 5 Read: Format Data Digits (Variable) Checksum (Optional) Max./Min. code length: Refer to Max./Min. code length of Code-39. Truncat

Seite 43

Truncate leading 0-15 00-15 00* Truncate ending 0-15 00-15 00* Code ID setting 00-ffH ASCII code 00-ffH < i >* Insert group selection 00-44

Seite 44 - Interleaved 2 of 5

Matrix 2 of 5 Eur Read: Format Data Digits (Variable) Checksum (Optional) Checksum Verification: The checksum is made as the sum module 10 of the n

Seite 45

Weight 155 g (cable not included) 160 g (cable not included) Cable – K/B wedge Straight 2.0 m Cable – universal type Straight 2.3 m Connector type R

Seite 46

Checksum Transmission Disable Enable 00* 01 Max. code length 00-64 00-64 00* Min. code length 00-64 00-64 00* Truncate leading 0-15 00-

Seite 47 - Industrial 2 of 5

Codabar Read: Format Start Data Digits (Variable) Checksum (Optional) End Checksum Verification: The checksum is made as the sum module 16 of the nu

Seite 48

Checksum Transmission Disable Enable 00* 01 Max. code length 00-64 00-64 00* Min. code length 00-64 00-64 00* Truncate leading 0-15 00-15 00* T

Seite 49 - Matrix 2 of 5 Eur

Codabar Insertion group selection: Refer to Insertion group selection of UPCA. Start/End type: The Codabar has four pairs of Start/End pattern; you m

Seite 50

Code-128 Read: Format Data Digits (Variable) Checksum (Optional) Checksum Verification: The checksum is made as the sum module 103 of all data dig

Seite 51 - Codabar

Code-128 Max./Min. code length: Refer to Max./Min. code length of Code-39. Truncate leading/ending: Refer to Truncate leading/ending of UPCA. Code Id

Seite 52

Truncate leading 0-15 00-15 00* Truncate ending 0-15 00-15 00* Code ID setting 00-ffH ASCII code 00-ffH < # >* Insert group selection

Seite 53

Code-93 Read: Format Data Digits(Variable)Checksum1(Optional)Checksum2(Optional)Checksum Verification: The checksum is made as the sum module 47 of

Seite 54 - Code-128

Checksum Transmission Disable Enable 00* 01 Max. code length 00-64 00-64 00* Min. code length 00-64 00-64 00* Truncate leading 0-15 00-15 00

Seite 55

Code-11 Read: Format Data Digits(Variable)Checksum1(Optional)Checksum2(Optional)Checksum Verification: The checksum is presented as the sum module

Seite 56

Programming Programming method Manual (Reading special barcode) DOS command through RS-232, Windows configuration program Program upgrade Enabled by

Seite 57 - Code-93

Checksum Transmission Disable Enable 00* 01 Max. code length 00-64 00-64 00* Min. code length 00-64 00-64 00* Truncate leading 0-15 00-15 00* T

Seite 58

MSI/plessey Read: Format Data Digits(Variable)Checksum1(Optional)Checksum2(Optional)Checksum Verification: The MSI/Plessey has one or two optional c

Seite 59 - Code-11

Checksum Transmission Disable Enable 00* 01 Max. code length 00-64 00-64 00* Min. code length 00-64 00-64 00* Truncate leading 0-15 00-15 00* T

Seite 60

UK/plessey Read: Format Data Digits (Variable) Checksum1+2(Optional) Checksum Verification: The UK/Plessey has one or two optional checksum digits.

Seite 61 - MSI/plessey

Checksum Transmission Disable Enable 00* 01 Max. code length 00-64 00-64 00* Min. code length 00-64 00-64 00* Truncate leading 0-15 00-15 00* T

Seite 62

Telepen Read: IATA (International Air Transport Association). Checksum Verification: The checksum is presented as the sum module 10 or 11 of the data

Seite 63 - UK/plessey

Max. code length 00-64 00-64 00* Min. code length 00-64 00-64 00* Truncate leading 0-15 00-15 00* Truncate ending 0-15 00-15 00* Code ID setti

Seite 64

Standard 2 of 5 Read: Format Data Digits (Variable) Checksum1(Optional) Max./Min. code length: Refer to Max./Min. code length of Code-39. Truncat

Seite 65 - Telepen

Truncate leading 0-15 00-15 00* Truncate ending 0-15 00-15 00* Code ID setting 00-ffH ASCII code 00-ffH < i >* Insert group selection 00

Seite 66

RSS-14 Read: Format Data Digits (Variable) Checksum1(Optional) Max./Min. code length: Refer to Max./Min. code length of Code-39. Truncate leading/e

Seite 67 - Standard 2 of 5

Programming the 8110/8150/8210 To program the 8110/8150/8210, you must scan a series of programming barcode in the correct order. Fold out the back c

Seite 68

Truncate leading 0-15 00-15 00* Truncate ending 0-15 00-15 00* Code ID setting 00-ffH ASCII code 00-ffH < R4 >* Insert group selection 0

Seite 69

RSS-Limited Read: Format Data Digits (Variable) Checksum1(Optional) Max./Min. code length: Refer to Max./Min. code length of Code-39. Truncate le

Seite 70

Min. code length 00-64 00-64 01* Truncate leading 0-15 00-15 00* Truncate ending 0-15 00-15 00* Code ID setting 00-ffH ASCII code 00-ffH <

Seite 71

RSS-Expanded Read: Format Data Digits (Variable) Checksum1(Optional) Max./Min. code length: Refer to Max./Min. code length of Code-39. Truncate l

Seite 72

Min. code length 00-64 00-99 01* Truncate leading 0-15 00-15 00* Truncate ending 0-15 00-15 00* Code ID setting 00-ffH ASCII code 00-ffH <

Seite 73

China Post Read: Format Data Digits (Variable) Checksum1(Optional) Max./Min. code length: Refer to Max./Min. code length of Code-39. Truncate lea

Seite 74

Truncate leading 0-15 00-15 00* Truncate ending 0-15 00-15 00* Code ID setting 00-ffH ASCII code 00-ffH < t >* Insert group selec

Seite 75

Italian Pharmacode Read: Format Data Digits (Variable) Checksum1(Optional) Max./Min. code length: Refer to Max./Min. code length of Code-39. Trun

Seite 76

Min. code length 00-64 00-64 09* Truncate leading 0-15 00-15 00* Truncate ending 0-15 00-15 00* Code ID setting 00-ffH ASCII code 0

Seite 77

Code-16K Only the ZB-8210 can decode Code-16K. Truncate leading/ending: Refer to Truncate leading/ending of UPCA. Code Id setting: Refer to Code ID se

Seite 78

Option Bar Code Option Alphanumeric Entry Interface selection Keyboard Wedge RS-232 Wand emulation USB Keyboard/RS-232 Auto detection reser

Seite 79 - Code-16K

PDF-417 Only the ZB-8210 can decode PDF-417. Truncate leading/ending: Refer to Truncate leading/ending of UPCA. Code Id setting: Refer to Code ID sett

Seite 80 - PDF-417

String setting Prefix characters: Up to 22 ASCII characters may be sent before data digits. Prefix Data Digits Suffix Suffix characters: Up to 22 ASCI

Seite 81 - String setting

Preamble characters setting None 1-22 characters00* 00-ffH ASCII code Postamble characters setting None 1-22 characters00* 00-ffH ASCII code Insert G1

Seite 82

String setting Insert G1/G2/G3/G4 character setting: The scanner offer 4 positions and 4 characters to insert among the symbol. Example: Barcode “1 2

Seite 83

Insert G3 characters setting None 1-22 characters00* 00-ffH ASCII code Insert G4 characters setting None 1-22 characters00* 00-ffH ASCII code Exit

Seite 84

Transmission Preamble transmission: By setting Enable, Preamble will be appended before the data transmitted. Postamble transmission: By setting

Seite 85 - Transmission

Insert data group 1 position 00-64 (00: no insertion)00-64 00* Insert data group 2 position 00-64 (00: no insertion)00-64 00* Insert data group 3 pos

Seite 86

Transmission Code ID transmission: If your application is needed to transmit Code ID, you must set this to Proprietary ID or AIM ID. Code length tra

Seite 87

Code length transmission Disable Enable 00* 01 Code name transmission Disable Enable 00* 01 Case conversion Disable Upper case Lower case *For barcod

Seite 88

Test Chart CODABAR-PARA CODE-11 PARA CODE-128 PARA CODE-39 PARA CODE-93 PARA EAN-13 PARA 89

Seite 89

Interface Selection This decoder build-in scanner comes in one model and supports interfaces such as keyboard wedge, RS232 serial wedge, wand emulati

Seite 90

PDF-417 STANDRAD-25 PARA CODE-16K EAN-8 PARA INDUSTRIAL-25 PARA UPCE PARA 8754990

Seite 91

INTERLEAVED-25 PARA MATRIX 25 PARA MSI/PLESSEY PARA UPCA PARA UK/PLESSEY PARA 91

Seite 92 - ASCII Code Table

ASCII Code Table Note: For keyboard wedge only. L H 0 1 0 1 0 Null NUL DLE 1 Up F1 SOH DC1 2 Down F2 STX DC2 3 Left F3

Seite 93 - Parameter Setting List

Parameter Setting List Program Barcode standard parameter setting list If you wish to display the current configuration of your ZB-8110/8150/82

Seite 94

Firmware version list If you wish to display the firmware version, scan the Firmware version list. WARNING: Default value initialization If you

Seite 95

97 0A1B2C3D4E5F678Finish995

Kommentare zu diesen Handbüchern

Keine Kommentare